Serviced air conditioning system amps and charge both good Cleaned condenser air filter good cycled everything is working good at this time
Serviced Lenox air conditioning system amps good, air filter good, cycled checked charge is at 30 degree coil temp, 60 outside temp. Coil temp should come up with outside temp. R22 system, cleaned coil, everything working good at this time
Completed clean and check on air conditioner, replaced customer supplied air filter, checked pressures and temperatures checked amps and capacitors all within manufacture specifications, cleaned and washed condenser, system is working properly at this time
Upon arrival checked in with customer to gain access to equipment, customer stated that system didn't seem to be cooling properly, filter was just replaced, made call for cooling from thermostat system started indoor fan came on, went out to check condenser and found compressor running but fan was not spinning, spun by hand and the fan started operating, checked capacitor and was reading 0 mfd on fan side, replaced with new 60/5 dual capacitor and cycled system compressor and fan started properly checked amps checked pressures and temperatures all within manufacture specifications. System is operating properly at this time.
Serviced Lenox air conditioning system amps and charge both good Cleaned condenser air filter good cycled everything is working good at this time
arrived on site and checked in with customer to gain access to equipment, customer stated that she turned the ac on yesterday but it never cooled down and shut it off. Made call for cooling from thermostat and system started normal connected gauges to check refrigerant and found was low added 1 pound of 410a to system, did a visual inspection for leaks and found liquid line fitting on evaporator coil was loose tightened fitting and did not see any oil or refrigerant leaks did see some oil residue on top of furnace which was present from the loose connection after adjusting charge also cleaned condenser coil that was very dirty, pressures and temperatures all within manufacture specifications and system is operating and cooling properly at this time
Completed clean and check of Trane air conditioner checked filter checked pressure and temperatures checked amps and capacitor all within manufacture specifications cleaned and washed condenser system is operating properly at this time
Found system low added 1 pound 410a, bubble checked condenser, there was oil around bottom of coil, will send over quote for replacement. Serviced air conditioning system amps and charge both good Cleaned condenser air filter replaced,
Cleaned and checked Carrier air conditioner. checked filter still good, checked pressures and temperatures, checked amps and capacitor all within manufacture specifications, cleaned and washed condenser. System is operating and cooling properly.
Serviced air conditioning system amps and charge both good Cleaned condenser air filter good cycled everything is working good at this time
Completed clean and check on Carrier air conditioner, checked air filter and is still new looking, checked pressures and temperatures, checked amps, tested capacitor all within manufacture specifications, cleaned and washed condenser, system is operating and cooling properly at this time
Found system low added 2 pounds 410a, serviced air conditioning system amps and charge both good Cleaned condenser air filter good cycled everything is working good at this time
Completed clean and check of air conditioner checked air filter customer just replaced, checked pressures and temperatures, checked amps checked capacitor all within manufacture specifications cleaned and washed condenser system is operating correctly at this time.
Replaced bad condenser fan motor and capacitor, checked charge Cycled system everything working
Serviced air conditioning system amps and charge both good, found breaker tripped, replaced bad capacitor, checked everything is working good at this time
Service Carrier air conditioner
Serviced both Carrier air conditioning systems amps and charge both good Cleaned condenser air filter good, cycled everything is working good at this time
Serviced Carrier air conditioning system amps and charge both good Cleaned condenser, filter good, humidifier pad will be changed in the fall, cycled everything is working good at this time
Completed Carrier air conditioner clean and check. Checked air filter still good. Checked pressures and temperatures, checked amps, checked capacitor all within manufacture specifications, cleaned and washed condenser, system is operating and cooling properly at this time.
Serviced air conditioning system amps and charge both good Cleaned condenser air filter good cycled everything is working good at this time
Serviced Carrier air conditioning system amps and charge both good Cleaned condenser air filter good cycled everything is working good at this time
Serviced Lennox air conditioning system amps and charge both good Cleaned condenser air filter good cycled everything is working good at this time
Serviced both Carrier air conditioning systems amps and charge both good Cleaned condenser air filter replaced humidifier pad replaced, cycled everything is working good at this time
Serviced Carrier air conditioning system amps and charge both good Cleaned condenser air filter replaced, cycled everything is working good at this time
Serviced air conditioning system amps and charge both good Cleaned condenser air filter replaced, cycled everything is working good at this time